What is Mechanical Calibration?

Our NABL-accredited services validate dimensional (0-300mm), speed (10–100,000 RPM), and acoustic (30–130 dB) instruments, including micrometers, calipers, tachometers, sound level meters, and torque wrenches (0.1–300 Nm), ensuring precision in measurements for and medical device applications.

Why is it Critical?

Accurate calibration is vital for ensuring process reliability, product quality, and compliance with GMP and regulatory standards in manufacturing and medical device production, minimizing risks of non-compliance.

Our Role in Your Compliance

Indivirtus Healthcare Services provides traceable, high-precision calibration to enhance operational efficiency and ensure audit readiness, empowering companies with reliable instrument performance for seamless operations.

Our Expert Calibration Approach

At Indivirtus Healthcare Services, we adopt a meticulous and standards-compliant calibration approach to ensure dimensional and mechanical measurement accuracy across industrial and laboratory instruments. Our calibration services are conducted in accordance with ISO/IEC 17025:2017 and traceable to NPL/NIST, ensuring reliability, repeatability, and regulatory compliance.

We tailor our calibration services to your specific requirements, providing customized solutions that optimize performance in critical processes. Our comprehensive documentation supports FDA, EMA, and other regulatory audits, ensuring your instruments maintain GMP compliance and operational reliability.

Mechanical Calibration Deliverables

NABL-Accredited Calibration Certificate: Official certification ensuring compliance with ISO/IEC 17025:2017 standards.

Measurement Uncertainty Analysis: Detailed analysis quantifying measurement reliability and accuracy.

Out-of-Tolerance (OOT) Notification (If Applicable): Immediate alert for any instrument found out of tolerance

On-Site and In-Lab Services: Depending on customer needs, we offer both in-house lab calibration and on-site services, ensuring minimal downtime and maximum convenience as per our Accredited NABL Scope.

Calibration Due Reminder Service/ Reminder Alerts for Next Calibration: Notifications sent before instrument due dates/ Advance notifications for due calibration to maintain compliance

Preventive Feedback (If Required):
• Suggestions for repair, maintenance, or re-calibration
• Identification of instruments beyond repair or out of tolerance
• Alert on environmental or handling issues impacting performance

Regulatory Compliance & Global Standards

At Indivirtus Healthcare Services Pvt Ltd, our mechanical and dimensional calibration services strictly adhere to both national and international metrological standards, ensuring accuracy, traceability, and compliance across critical industries such as pharmaceuticals, automotive, aerospace, engineering, and manufacturing.

  • ISO/IEC 17025:2017: General requirements for the competence of testing and calibration laboratories. It ensures valid results, technical proficiency, and traceability.
  • 21 CFR Part 11 (FDA): Governs electronic records and signatures—applicable if digital systems are used in calibration documentation.
  • Good Manufacturing Practices (GMP): Ensures measurement equipment used in regulated environments (like pharma) is properly calibrated and traceable.
  • ISO/IEC Guide 98 (GUM): Guide to the Expression of Uncertainty in Measurement – for reporting uncertainty.
  • NIST/NPL Standards: Reference standards used for traceability to national/international measurements.
  • IS/ISO standards: relevant to Mechanical & Dimensional Calibration.

Applications & Use Cases

Our mechanical calibration services are essential for companies and medical device manufacturers engaged in manufacturing, quality control, and process validation. Accurate dimensional, speed, and acoustic measurements are critical for reliable operations and product quality. Key use cases include calibrating micrometers and calipers for precise component measurements, validating tachometers for equipment speed monitoring, and ensuring sound level meters meet occupational safety standards, supporting regulatory audits and global market compliance.

Why Choose Indivirtus Healthcare

Indivirtus Healthcare Services combines certified expertise and global regulatory knowledge to deliver unmatched mechanical calibration solutions. Our team ensures scientifically defensible results, rapid turnaround times, and strict confidentiality to protect your proprietary data. With a commitment to precision and compliance, we help you achieve operational excellence and maintain trust in your and medical device processes.

Frequently Asked Questions

Frequently Asked Questions

What is mechanical/dimensional calibration?

Mechanical or dimensional calibration involves verifying the accuracy of physical measuring instruments (e.g., calipers, micrometers, dial indicators) by comparing them against standard references traceable to national or international standards.

How often should mechanical instruments be calibrated?

Typically once every 12 months, but the frequency may vary based on:
• Usage intensity
• Environmental conditions
• Regulatory requirements
• Customer SOPs or audit recommendations

Are your calibrations traceable to national or international standards?

Yes. All calibrations are traceable to NPL (National Physical Laboratory – India) or international bodies like NIST (USA), DKD (Germany), or OIML through NABL-accredited reference equipment.

Do you offer calibration at our site (onsite service)?

Yes, we provide onsite calibration for mechanical instruments where feasible, especially for large equipment like surface plates, height gauges, or production setups.

What if my instrument is found out of tolerance?

If the instrument is out of tolerance:
• We notify you before proceeding further
• Recommend adjustment, repair, or replacement